CrossRef enabled

PAC Archives

Archive →

Pure Appl. Chem., 2001, Vol. 73, No. 10, pp. 1579-1588

http://dx.doi.org/10.1351/pac200173101579

Evolution and revolution in instrumentation for plasma-source mass spectrometry

Gary M. Hieftje1*, James H. Barnes1, Ole A. Grøn1, Andrew M. Leach2, Denise M. McClenathan1, Steven J. Ray1, David A. Solyom3, William C. Wetzel1, M. Bonner Denton4 and David W. Koppenaal5

1 Department of Chemistry, Indiana University, Bloomington, IN 47405, USA
2 Present address: Department of Chemistry, Stanford University, Stanford, CA 94305, USA
3 Present address: Honeywell FM&T, Kansas City, MO 64141-6159, USA
4 Department of Chemistry, University of Arizona, Tucson, AZ 85724, USA
5 Pacific Northwest National Laboratory, Richland, WA 99352, USA

CrossRef Cited-by theme picture

CrossRef Cited-by Linking

  • Marzouk E. R., Chenery S. R., Young S. D.: Measuring reactive metal in soil: a comparison of multi-element isotopic dilution and chemical extraction. Eur J Soil Sci 2013, 64, 526. <http://dx.doi.org/10.1111/ejss.12043>
  • Antes Fabiane G., Mesko Márcia F., Barin Juliano S., Moreira Clarissa M., Flores Érico M.M., Dressler Valderi L.: Development of multi-elemental method for quality control of parenteral component solutions using ICP-MS. Microchemical Journal 2011, 98, 144. <http://dx.doi.org/10.1016/j.microc.2010.12.010>
  • Schilling Gregory D., Ray Steven J., Sperline Roger P., Denton M. Bonner, Barinaga Charles J., Koppenaal David W., Hieftje Gary M.: Optimization of Ag isotope-ratio precision with a 128-Channel array detector coupled to a Mattauch-Herzog mass spectrograph. J Anal At Spectrom 2010, 25, 322. <http://dx.doi.org/10.1039/b914052b>
  • Bleiner Davide, Bogaerts Annemie: Computer simulations of sample chambers for laser ablation–inductively coupled plasma spectrometry. ATOM SPECTROSC 2007, 62, 155. <http://dx.doi.org/10.1016/j.sab.2007.02.010>
  • Bleiner Davide, Bogaerts Annemie: Computer simulations of laser ablation sample introduction for plasma-source elemental microanalysis. J Anal At Spectrom 2006, 21, 1161. <http://dx.doi.org/10.1039/b607627k>
  • Bol'shakov Aleksandr A, Ganeev Aleksandr A, Nemets Valerii M: Prospects in analytical atomic spectrometry. RUSS CHEM REV 2006, 75, 289. <http://dx.doi.org/10.1070/RC2006v075n04ABEH001174>
  • Ramakumar K. L.: Analytical challenges in characterization of high purity materials. Bull Mater Sci 2005, 28, 331. <http://dx.doi.org/10.1007/BF02704245>
  • Holliday Alison E., Beauchemin Diane: Spatial profiling of analyte signal intensities in inductively coupled plasma mass spectrometry. ATOM SPECTROSC 2004, 59, 291. <http://dx.doi.org/10.1016/j.sab.2003.12.018>
  • BALCERZAK Maria: An Overview of Analytical Applications of Time of Flight-Mass Spectrometric (TOF-MS) Analyzers and an Inductively Coupled Plasma-TOF-MS Technique. Anal Sci 2003, 19, 979. <http://dx.doi.org/10.2116/analsci.19.979>
  • Current literature in mass spectrometry. J Mass Spectrom 2002, 37, 545. <http://dx.doi.org/10.1002/jms.252>