CrossRef enabled

PAC Archives

Archive →

Pure Appl. Chem., 1987, Vol. 59, No. 5, pp. 663-672

http://dx.doi.org/10.1351/pac198759050663

Fibre-optic sensors in biomedical sciences

O. S. Wolfbeis

CrossRef Cited-by theme picture

CrossRef Cited-by Linking

  • Prakash John, Mishra A K: Fabrication, optimization and application of a dip-probe fluorescence spectrometer based on white-light excitation fluorescence. Meas. Sci. Technol. 2013, 24, 105502. <http://dx.doi.org/10.1088/0957-0233/24/10/105502>
  • Juita  , Dlugogorski Bogdan Z, Kennedy Eric M, Mackie John C: Low temperature oxidation of linseed oil: a review. Fire Sci Rev 2012, 1, 3. <http://dx.doi.org/10.1186/2193-0414-1-3>
  • FUJIWARA Yuki, ISHIKAWA Yuichi, AMAO Yutaka: Properties of an Optical Sensor Based on Luminescence Quenching of Platinum Porphyrin and Perylene Immobilized in a Polystyrene Film. NIPPON KAGAKU KAISHI 2002, 261. <http://dx.doi.org/10.1246/nikkashi.2002.261>
  • Furuto Takako, Lee Sang-Kyung, Amao Yutaka, Asai Keisuke, Okura Ichiro: Oxygen sensing system using triplet–triplet reflectance of zinc porphyrin immobilized in polymer membrane studies by laser flash photolysis. J Photochem Photobiol A Chem 2000, 132, 81. <http://dx.doi.org/10.1016/S1010-6030(00)00203-3>
  • Merchant D.F, Scully P.J, Schmitt N.F: Chemical tapering of polymer optical fibre. Sensor and Actuators 1999, 76, 365. <http://dx.doi.org/10.1016/S0924-4247(99)00008-4>
  • Grant Sheila A, Glass Robert S: A sol–gel based fiber optic sensor for local blood pH measurements. Actuat B 1997, 45, 35. <http://dx.doi.org/10.1016/S0925-4005(97)00263-3>
  • Cruces Blanco C., Segura Carretero A., Fernández Gutierrez A., Román Ceba M.: Micellar-enhanced synchronous-derivative fluorescence determination of derivatized folic acid in pharmaceutical preparations. J  Pharm Biomed Anal 1995, 13, 1019. <http://dx.doi.org/10.1016/0731-7085(95)01530-X>
  • Mendes Sergio B., Li Lifeng, Burke James J., Lee John E., Saavedra S. Scott: 70-nm-bandwidth achromatic waveguide coupler. Appl Opt 1995, 34, 6180. <http://dx.doi.org/10.1364/AO.34.006180>
  • Frishman G., Gabor G.: Surface characteristics of optical chemical sensors. Actuat B 1994, 17, 227. <http://dx.doi.org/10.1016/0925-4005(93)00879-4>
  • Sethi Rajinder S.: Transducer aspects of biosensors. Biosensors bioelectronics 1994, 9, 243. <http://dx.doi.org/10.1016/0956-5663(94)80127-4>
  • Lakowicz Joseph R., Szmacinski Henryk: Fluorescence lifetime-based sensing of pH, Ca2+, K+ and glucose. Actuat B 1993, 11, 133. <http://dx.doi.org/10.1016/0925-4005(93)85248-9>
  • Shriver-Lake Lisa C., Ogert Robert A., Ligler Frances S.: A fiber-optic evanescent-wave immunosensor for large molecules. Actuat B 1993, 11, 239. <http://dx.doi.org/10.1016/0925-4005(93)85261-8>
  • Krull U. J., Brown R. S., Vandenberg E. T., Heckl W. M.: Determination of the physical structure of biological materials at biosensor interfaces by techniques of increasing magnification from microscopic to molecular scale. J Elec Microsc Tech 1991, 18, 212. <http://dx.doi.org/10.1002/jemt.1060180303>
  • Leiner Marc J.P.: Luminescence chemical sensors for biomedical applications: scope and limitations. Analytica Chimica Acta 1991, 255, 209. <http://dx.doi.org/10.1016/0003-2670(91)80049-Y>
  • Gautier Sabine M., Blum Loïc J., Coulet Pierre R.: Bioluminescence-based fibre-optic sensor with entrapped co-reactant: an approach for designing a self-contained biosensor. Analytica Chimica Acta 1991, 243, 149. <http://dx.doi.org/10.1016/S0003-2670(00)82553-2>
  • Gautier Sabine M., Blum Loïc J., Coulet Plerre R.: Fibre-optic biosensor based on luminescence and immobilized enzymes: Microdetermination of sorbitol, ethanol and oxaloacetate. J Biolumin Chemilumin 1990, 5, 57. <http://dx.doi.org/10.1002/bio.1170050112>
  • Badertscher Martin, Musso Stefano, Welti Martin, Pretsch Ernö, Maruizumi Takuya, Ha Tae-kyu: Combined application of pair potentials and the MM2 force field for the modeling of ionophores. J Comput Chem 1990, 11, 819. <http://dx.doi.org/10.1002/jcc.540110705>
  • Gautier Sabine M., Blum Loïc J., Coulet Pierre R.: Alternate determination of ATP and NADH with a single bioluminescence-based fiber-optic sensor. Actuat B 1990, 1, 580. <http://dx.doi.org/10.1016/0925-4005(90)80277-7>
  • Gautier Sabine M., Blum Loöic J., Coulet Pierre R.: Multi-function fibre-optic sensor for the bioluminescent flow determination of ATP or NADH. Analytica Chimica Acta 1990, 235, 243. <http://dx.doi.org/10.1016/S0003-2670(00)82081-4>
  • Dremel Bernd A.A., Yang Wansheng, Schmid Rolf D.: On-line determination of lactic acid during kefir fermentation based on a fibre-optic lactic acid biosensor and flow-injection analysis. Analytica Chimica Acta 1990, 234, 107. <http://dx.doi.org/10.1016/S0003-2670(00)83544-8>
  • Xie Xiangfang, Suleiman Ahmad A., Guilbault George G.: A Urea Fiber Optic Biosensor Based on Absorption Measurement. Anal Lett 1990, 23, 2143. <http://dx.doi.org/10.1080/00032719008052556>
  • Blum Loïc J., Gautier Sabine M., Coulet Pierre R.: Design of luminescence photobiosensors. J Biolumin Chemilumin 1989, 4, 543. <http://dx.doi.org/10.1002/bio.1170040171>
  • Bryan Aiden J., de Silva A.Prasanna, De Silva Saliya A., Rupasinghe R.A.D.Dayasiri, Sandanayake K.R.A.Samankumara, Gautier S.M., Blum L.J., Coulet P.R.: Photo-induced electron transfer as a general design logic for fluorescent molecular sensors for cations. Biosensors 1989, 4, 169. <http://dx.doi.org/10.1016/0265-928X(89)80018-5>
  • Coulet P.R., Blum L.J., Gautier S.M.: Optically-based chemical and biochemical sensors for the detection of some drugs and biological compounds. J  Pharm Biomed Anal 1989, 7, 1361. <http://dx.doi.org/10.1016/0731-7085(89)80141-4>
  • Schaffar Bernhard P.H., Wolfbeis Otto S.: A calcium-selective optrode based on fluorimetric measurement of membrane potential. Analytica Chimica Acta 1989, 217, 1. <http://dx.doi.org/10.1016/S0003-2670(00)80382-7>
  • Dremel Bernd A.A., Schaffar Bernhard P.H., Schmid Rolf D.: Determination of glucose in wine and fruit juice based on a fibre-optic glucose biosensor and flow-injection analysis. Analytica Chimica Acta 1989, 225, 293. <http://dx.doi.org/10.1016/S0003-2670(00)84618-8>
  • Kallury Krishna M.R., Ghaemmaghami Vida, Krull U.J., Thompson Michael, Davies Martyn C.: Immobilization of phospholipids on silicon, platinum, indium/tin oxide and gold surfaces with characterization by x-ray photoelectron spectroscopy and time-of-flight secondary-ion mass spectrometry. Analytica Chimica Acta 1989, 225, 369. <http://dx.doi.org/10.1016/S0003-2670(00)84626-7>
  • Perkins Richard A., Jones Michael C.: Fiber-optic fluorescence array to study free convection in porous media. Rev Sci Instrum 1989, 60, 3492. <http://dx.doi.org/10.1063/1.1140499>
  • Physikalische Chemie 1987. Nachr Chem Tech Lab 1988, 36, 169. <http://dx.doi.org/10.1002/nadc.19880360208>
  • Wolfbeis Otto S., Sharma Ashutosh: Fibre-optic fluorosensor for sulphur dioxide. Analytica Chimica Acta 1988, 208, 53. <http://dx.doi.org/10.1016/S0003-2670(00)80735-7>
  • Arnold Mark A., Meyerhoff Mark E.: Recent Advances in the Development and Analytical Applications of Biosensing Probes. C R C Critical Reviews in Analytical Chemistry 1988, 20, 149. <http://dx.doi.org/10.1080/00078988808048811>